DYMATIC, INC
5328 N. Northwest Hwy.
Chicago, IL 60630-1137 USA
TEL:  
773-763-2100 FAX: 773-763-6877





                                Our 20th year  of
 Selling "Surplus Inventories, at Surplus Prices"

 .
For Price and Delivery
E-mail us at: sales@oemsurplus911.com or Call Us at: 773-763-2100
.

Home Index by Mfg Hydraulics Pneumatics Automotive Electrical Filters Casters About Us

Index by Mfg.

Aeroquip
Airroyal Cylinders  
Allen Bradley
Alco Valve
Al Xander / AXCO
Allied Witan
American Coupling
American Heat Exch.
Ametek / US Gauge
Anchor Fittings
Aro Modernair
Aschroft Gauge
Aschroft / Dresser
Atlas Cylinders
Autoclave Eng.
Barksdale
Bendix Aerospace
    / Lucas

Bearings
Bijur
Bimba
Bodine Motors
Borg and Warner
Brand Hydraulics
Brown & Scharpe
Browning
Brunning Parker
C.A. Norgren
Cessna
Char- Lynn
Circle Seal
Commercial Shearing

Continental Hyd.
Cross Mfg.
Daman Subplate
Danfoss
Data Logic
Delta Power
Deltrol
73 Mfg. Co.
Denison Hydraulics

Detroit Coil
Double A Hydraulics
Dowty
Duff Norton
Dwyer
Eastern / LFE
Enerpac
Facet Filters
Fairchild
Firestone
Fischer & Porter
Fram Filters
Gates Fittings
Generant
Gresen
Haenni Gauges
Hedland
Helicoide
Hi-Flex Fittings
HTC
Hub City
Hycon
Hydreco
Hydro-Craft
Imperial Eastman

Jaco
Kebby Tank Acc.
Keystone Valves
Legris
Lenz Fittings
Lenz Filters
Lenz Gauges
Lexair / Airmatic
LittleFuse
Lha
Lube Devices
Lucas / Bendix
Main Flanges
Manastrip
Microswitch
NCC
Norgren
Norman Filters
  (Ultraporous)
Numatics
Nycoil
Oil Dyne
Oil Gear / Hydura

Parker Hydraulics
Parker Fittings
Perfecting
Pepperl & Fuchs
Plast-O-Matic
Prince
Purolator
Racine
Refilco
Rexroth
Ringfeder
Ross - TRW
Schroder
Squre D
Skinner Valves
Skinner Parts
Snap-tite Couplings
Snap-Tite Valves
SOR
Specialty Products
Sta-rite
Strahmann Valves
Stratoflex Fittings
Sauer Sundstrund
Suntech-
         Sundstrand
Swagelock Fittings
Synflex Fittings
Telemecanique
Tyrone
UCC
Ultraporous Filters
U.S. Gauge
Utec
Veriflo
Versa
Vican Pumps
Vickers
Viking
Watts Regulator
Weatherhead
Weschler / NES
White
Young Radiators
Zinga
Zycron

Vickers Compatible Hydraulic Directional Control Valves
In Stock Inventory Listing

 

Vickers DG4V-3 Compatible,
D03 / ISO-03 Solenoid Operated Directional Valves
Valve Size: D03 (Formerly D01)
Mounting: D03 Subplate Mounting (Formerly D01)
Made in Japan             Spg. Weight: 6 LBS
 

 

SIZE D03
SINGLE SOLENOID 2 POSITION SPRING OFFSET TYPE

 

Part Numbers provided for reference only!
Please refer to symbol and description for exact specifications!

 
Item# Compare to Nachi #
Compare to Hyvair #
Compare to Vickers #
JIS Symbol
(Click o Enlarge)
Description Max Pressure
PSI
Max. Flow
GPM
Coil &
Voltage
In Stock
Qty
7071 NCH SA-G01-A2X-C1-E**
D03SD-1A8-100A-**
DG4V-3-22A-U-100V-**
Single Solenoid, 2 Position
Spring Offset, Closed Crossover
(P to A, B & T Closed)
5000 7.9 100 VAC
DIN Connector
3
7092 NCH SS-G01-A2X-R-C115-E**
D03S-1A8-115A-**
DG4V-3-22A-WL-B-**
Single Solenoid, 2 Position
Spring Offset, Closed Crossover
(P to A, B & T Closed)
Indicator Light
5000 7.9 115 VAC
Terminal Box
35
7072 NCH SA-G01-A3X-D1-E**
D03SD-1A-12D-**
DG4V-3-2A-U-G-**
Single Solenoid, 2 Position,
Spring Offset, Closed Crossover
(P to A, B to T)
5000 21.1 12 VDC
DIN Connector
3
7095 NCH SS-G01-A3X-R-C230-E**
D03S-1A-230AL-**
DG4V-3-2A-WL-D-**
Single Solenoid, 2 Position,
Spring Offset, Closed Crossover
(P to A, B to T)
Indicator Light
5000 21.1 230 VAC
Terminal Box
10
7096 NCH SS-G01-A3Z-GR-D2-E**
D03S-1AY-24DL-**
DG4V-3-0A-WL-D-**
Single Solenoid, 2 Position,
Spring Offset, Open Crossover
(P to A, B to T)
Indicator Light, Electrical Surge Control
5000 17.1 24 VDC
Terminal Box
10
7097 NCH SS-G01-A3Z-R-??-E**
D03S-1AY-??-**
DG4V-3-0A-WL-?-**
Single Solenoid, 2 Position,
Spring Offset, Open Crossover
(P to A, B to T)
Indicator Light
5000 17.1 - 1
7085 NCH SA-G01-H3X-D2-E**
D03SD-1AR-24D-**
DG4V-3-2AL-U-H-**
Single Solenoid, 2 Position,
Spring Offset, Closed Crossover,
P to B, A to T
5000 21.1 24 VDC
DIN Connector
10
7116 NCH SS-G01-H3X-R-C230-E**
D03S-1AR-230AL-**
DG4V-3-2AL-WL-D-**
Single Solenoid, 2 Position,
Spring Offset, Closed Crossover,
P to B, A to T
Indicator Light
5000 21.1 230 VAC
Terminal Box
10
7117 NCH SS-G01-H3X-R-E115-E**
D03S-1AR-115AL-**
DG4V-3-2AL-WL-B-**
Single Solenoid, 2 Position,
Spring Offset, Closed Crossover,
P to B, A to T
Indicator Light
5000 21.1 115 V
Rectified
Terminal Box
5
7090 NCH SS-G01-A04-R-D2-E**
D03S-5H-24DL-**
DG4V-3-0B-WL-H-**
Single Solenoid, 2 Position
Spring Offset/Spring Center,
All Ports Open
Indicator Light
5000 13.2 24 VDC
Terminal Box
10
7098 NCH SS-G01-A5-R-D1-E**
D03S-5B-12DL-**
DG4V-3-2B-WL-G-**
Single Solenoid, 2 Position,
Spring Offset/Spring Center,
All Ports Blocked
Indicator Light
5000 26.4 12 VDC
Terminal Box
5
7118 NCH SS-G01-H5-R-E115-E**
D03S-5BR-115AL-**
DG4V-3-2BL-WL-B-**
Single Solenoid, 2 Position,
Spring Offset/Spring Center,
All Ports Blocked
Indicator Light
5000 26.4 115 V
Rectified
Terminal Box
5
 

 

 SIZE D03
DOUBLE SOLENOID 2 POSITION DETENT

 

Part Numbers provided for reference only!
Please refer to symbol and description for exact specifications!

 
Item# Compare to Nachi #
Compare to Hyvair #
Compare to Vickers #
JIS Symbol
(Click o Enlarge)
Description Max Pressure
PSI
Max. Flow
GPM
Coil &
Voltage
In Stock
Qty
7111 NCH SS-G01-E2X-R-D2-E**
D03S-3A8-24DL-35
DG4V-3-?N-WL-H-**
Double Solenoid, 2 Position,
Detent, Closed Crossover,
P to A, B & T Blocked
Indicator Light
5000 7.9 24 VDC
Terminal Box
5
7084 NCH SA-G01-E3X-C230-E**
D03SD-3A-230A-**
DG4V-3-2N-U-D-**
Double Solenoid, 2 Position,
Detent, Closed Crossover,
P to A, B to T
5000 26.4 230 VAC
DIN Connector
15
7112 NCH SS-G01-E3X-R-D1-E**
D03S-3A-12DL-**
DG4V-3-2N-WL-G-**
Double Solenoid, 2 Position,
Detent, Closed Crossover,
P to A, B to T
Indicator Light
5000 26.4 12 VDC
Terminal Box
5
7113 NCH SS-G01-E3Z-FR-D1-E**
D03SX-3AY-12DL-**
DG4V-3-0N-WL-G-**
Double Solenoid, 2 Position,
Detent, Open Crossover,
P to A, B to T, Shockless Type,
Indicator Light
3500 13.2 12 VDC
Terminal Box
3
7114 NCH SS-G01-E3Z-FR-E115-E**
D03SX-3AY-115AL-**
DG4V-3-0N-WL-B-**
Double Solenoid, 2 Position,
Detent, Open Crossover,
P to A, B to T, Shockless Type
Indicator Light
3500 13.2 115 V
Rectified
Terminal Box
5
7115 NCH SS-G01-E3Z-R-D2-E**
D03S-3AY-24DL-**
DG4V-3-0N-WL-H-**
Double Solenoid, 2 Position,
Detent, Open Crossover,
P to A, B to T,
Indicator Light
5000 17.1 24 VDC
Terminal Box
10
 

 
SIZE D03
DOUBLE SOLENOID 3 POSITION SPRING CENTER TYPE 
 

Part Numbers provided for reference only!
Please refer to symbol and description for exact specifications!

 
Item# Compare to Nachi #
Compare to Hyvair #
Compare to Vickers #
JIS Symbol
(Click o Enlarge)
Description Max Pressure
PSI
Max. Flow
GPM
Coil &
Voltage
In Stock
Qty
7073 NCH SA-G01-C1-C115-E**
D03SD-2K-115A-**
DG4V-3-3C-U-B-**
Double Solenoid, 3 Position,
Spring Center, A to T, T & B Blocked
5000 17.1 115 VAC
DIN Connector
1
7110 NCH SS-G01-C1S-R-C115-E**
D03S-2K1-115AL-**
DG4V-3-?C-WL-B-**
Double Solenoid, 3 Position,
Spring Center, A to T with Taper, T & B Blocked
Indicator Light
5000 26.4 115 VAC
Terminal Box
5
7074 NCH SA-G01-C4-C115-E**
D03SD-2H-115A-**
DG4V-3-0C-U-B-**
Double Solenoid, 3 Position,
Spring Center, All Ports Open
5000 13.2 115 VAC
DIN Connector
1
7075 NCH SA-G01-C4-D1-E**
D03SD-2H-12D-**
DG4V-3-0C-U-G-**
Double Solenoid, 3 Position,
Spring Center, All Ports Open
5000 13.2 12 VDC
DIN Connector
6
7077 NCH SA-G01-C4-D2-E**
D03SD-2H-24D-**
DG4V-3-0C-U-H-**
Double Solenoid, 3 Position,
Spring Center, All Ports Open
5000 13.2 24 VDC
DIN Connector
5
7078 NCH SA-G01-C4-F2-D1-E**
D03SDX-2H-12D-**
DG4V-3-0C-U-G-**
Double Solenoid, 3 Position,
Spring Center, All Ports Open
Shockless Type
3500 13.2 12 VDC
DIN Connector
1
7099 NCH SS-G01-C4-GR-D2-E**
D03S-2H-24DL-**
DG4V-3-0C-WL-H-**
Double Solenoid, 3 Position,
Spring Center, All Ports Open
Electrical Surge Control,
Indicator Light
5000 13.2 24 VDC
Terminal Box
5
7100 NCH SS-G01-C4-R-D1-E**
D03S-2H-12DL-**
DG4V-3-0C-WL-G-**
Double Solenoid, 3 Position,
Spring Center, All Ports Open
Indicator Light
5000 13.2 12 VDC
Terminal Box
3
7101 NCH SS-G01-C4-R-E115-E**
D03S-2H-115AL-**
DG4V-3-0C-WL-B-**
Double Solenoid, 3 Position,
Spring Center, All Ports Open
Indicator Light
5000 13.2 115 V
Rectified
Terminal Box
4
7102 NCH SS-G01-C5-FR-D1-E**
D03SX-2B-12DL-**
DG4V-3-2C-WL-G-**
Double Solenoid, 3 Position,
Spring Center, All Ports Blocked
Shockless Type, Indicator Light
3500 13.2 12 VDC
Terminal Box
5
7103 NCH SS-G01-C5-FR-E230-E**
D03SX-2B-230AL-**
DG4V-3-2C-WL-D-**
Double Solenoid, 3 Position,
Spring Center, All Ports Blocked
Shockless Type, Indicator Light
3500 13.2 230 V
Rectified
Terminal Box
10
7079 NCH SA-G01-C6-C115-E**
D03SD-2F-115A-**
DG4V-3-6C-U-B-**
Double Solenoid, 3 Position,
Spring Center, Pressure Port Blocked Center,
A & B to T, Motor, Float
5000 17.1 115 VAC
DIN Connector
1
7105 NCH SS-G01-C6-FR-E230-E**
D03SX-2F-230AL-**
DG4V-3-6C-WL-D-**
Double Solenoid, 3 Position,
Spring Center, Pressure Port Blocked Center,
A & B to T, Motor, Float
Shockless Type, Indicator Light
3500 13.2 230 V
Rectified
Terminal Box
10
7080 NCH SA-G01-C6S-C115-E**
D03SD-2F1-115A-**
DG4V-3-33C-U-B-**
Double Solenoid, 3 Position,
Spring Center, Pressure Port Blocked Center with Taper,
A & B to T, Motor, Float
5000 26.4 115 VAC
DIN Connector
3
7081 NCH SA-G01-C6S-C230-E**
D03SD-2F1-230A-**
DG4V-3-33C-U-D-**
Double Solenoid, 3 Position,
Spring Center, Pressure Port Blocked Center with Taper,
A & B to T, Motor, Float
5000 26.4 230 VAC
DIN Connector
5
7082 NCH SA-G01-C6S-D2-E**
D03SD-2F1-24D-**
DG4V-3-33C-U-H-**
Double Solenoid, 3 Position,
Spring Center, Pressure Port Blocked Center with Taper,
A & B to T, Motor, Float
5000 26.4 24 VDC
DIN Connector
5
7104 NCH SS-G01-C6S-R-D2-E**
D03S-2F1-24DL-**
DG4V-3-33C-WL-H-**
Double Solenoid, 3 Position,
Spring Center, Pressure Port Blocked Center with Taper,
A & B to T, Motor, Float, Indicator Light
5000 26.4 24 VDC
Terminal Box
5
7106 NCH SS-G01-C6S-FR-D2-E**
D03SX-2F1-24DL-**
DG4V-3-33C-WL-H-**
Double Solenoid, 3 Position,
Spring Center, Pressure Port Blocked Center with Taper,
A & B to T, Motor, Float, Shockless Type, Indicator Light
3500 13.2 24 VDC
Terminal Box
10
7083 NCH SA-G01-C7Y-D1-E**
D03SD-2C-12D-**
DG4V-3-8C-U-G-**
Double Solenoid, 3 Position,
Spring Center, A & B Blocked, P to C, Tandem Center
5000 13.2 12 VDC
DIN Connector
5
7107 NCH SS-G01-C7Y-FR-E230-E**
D03SX-2C-230AL-**
DG4V-3-8C-WL-D-**
Double Solenoid, 3 Position,
Spring Center, A & B Blocked, P to C, Tandem Center,
Shockless Type,
Indicator Lights
3500 10.6 230 V
Rectified
Terminal Box
5
7108 NCH SS-G01-C7Y-GR-D2-E**
D03S-2C-24DL-**
DG4V-3-8C-WL-H-**
Double Solenoid, 3 Position,
Spring Center, A & B Blocked, P to C, Tandem Center,
Electrical Surge Control, Indicator Light
5000 13.2 24 VDC
Terminal Box
6
7109 NCH SS-G01-C8-R-C115-E**
D03S-2C5-115AL-**
DG4V-3-1C-WL-B-**
Double Solenoid, 3 Position,
Spring Center, B Blocked, A & P to T,
Indicator Light
5000 13.2 115 VAC
Terminal Box
10
             

 


 

Vickers DG4S4 Compatible,
D05 / ISO-05 Solenoid Operated Directional Valves
Valve Size: D05 (Formerly D02)
Mounting: D05 Subplate Mounting (Formerly D02)
Maximum Operating Pressure: 3500 PSI
Made in Japan             Spg. Weight: 15 LBS
 

 

SIZE D05
SINGLE SOLENOID 2 POSITION SPRING OFFSET TYPE  

 

Part Numbers provided for reference only!
Please refer to symbol and description for exact specifications!

 
Item# Compare to Nachi #
Compare to Hyvair #
Compare to Vickers #
JIS Symbol
(Click o Enlarge)
Description Max Pressure
PSI
Max. Flow
GPM
Coil &
Voltage
In Stock
Qty
7124 NCH SS-G03-A3X-E115-E**
D05S-1A-115A-**
DG4S4-012A-W-B-**
Single Solenoid, 2 Position,
Spring Offset, Closed Crossover
(P to A, B to T)
3500 21.1 115 VAC
Rectified
Terminal Box
5
7125 NCH SS-G03-A3X-FR-D1-E**
D05SX-1A-12DL-**
DG4S4-012A-WL-G-**
Single Solenoid, 2 Position,
Spring Offset, Closed Crossover
(P to A, B to T), Shockless Type,
Indicator Light
3500 21.1 12 VDC
Terminal Box
10
7128 NCH SS-G03-A3X-R-D1-E**
D05S-1A-12DL-**
DG4S4-012A-WL-G-**
Single Solenoid, 2 Position,
Spring Offset, Closed Crossover
(P to A, B to T),
Indicator Light
3500 21.1 12 VDC
Terminal Box
10
7129 NCH SS-G03-A3Z-FR-D1-E**
D05SX-1AY-12DL-**
DG4S4-010A-WL-G-**
Single Solenoid, 2 Position,
Spring Offset, Open Crossover,
(P to A, B to T), Shockless Type
Indicator Light
3500 21.1 12 VDC
Terminal Box
15
7131 NCH SS-G03-A3Z-FR-D2-E**
D05SX-1AY-24DL-**
DG4S4-010A-WL-H-**
Single Solenoid, 2 Position,
Spring Offset, Open Crossover,
(P to A, B to T), Shockless Type
Indicator Light
3500 21.1 24 VDC
Terminal Box
4
7133 NCH SS-G03-A3Z-FR-E115-E**
D05SX-1AY-115AL-**
DG4S4-010A-WL-B-**
Single Solenoid, 2 Position,
Spring Offset, Open Crossover,
(P to A, B to T), Shockless Type
Indicator Light
3500 21.1 115 VAC
Rectified
Terminal Box
25
7136 NCH SS-G03-A3Z-R-D2-E**
D05S-1AY-24DL-**
DG4S4-010A-WL-H-**
Single Solenoid, 2 Position,
Spring Offset, Open Crossover,
(P to A, B to T),
Indicator Light
3500 21.1 24 VDC
Terminal Box
10
7137 NCH SS-G03-A3Z-R-D1-E**
D05S-1AY-12DL-**
DG4S4-010A-WL-G-**
Single Solenoid, 2 Position,
Spring Offset, Open Crossover,
(P to A, B to T),
Indicator Light
3500 21.1 12 VDC
Terminal Box
10
7138 NCH SS-G03-A3Z-R-E115-E**
D05S-1AY-115AL-**
DG4S4-010A-WL-B-**
Single Solenoid, 2 Position,
Spring Offset, Open Crossover,
(P to A, B to T),
Indicator Light
3500 21.1 115 VAC
Rectified
Terminal Box
9
7189 NCH SS-G03-H3X-R-C115-E**
D05S-1AR-115AL-**
DG4S4-012AL-WL-B-**
Single Solenoid, 2 Position,
Spring Offset, Closed Crossover,
P to B, A to T
Indicator Light
3500 21.1 115 VAC
Terminal Box
1
7191 NCH SS-G03-H3Z-R-D1-E**
D05S-1AYR-12DL-**
DG4S4-010AL-WL-G-**
Single Solenoid, 2 Position,
Spring Offset, Open Crossover,
P to B, A to T
Indicator Light
3500 21.1 12 VDC
Terminal Box
5
7192 NCH SS-G03-H3Z-R-C115-E**
D05S-1AYR-115AL-35
DG4S4-010AL-WL-B-**
Single Solenoid, 2 Position,
Spring Offset, Open Crossover,
P to B, A to T
Indicator Light
3500 21.1 115 VAC
Terminal Box
11
7122 NCH SS-G03-A04-R-C115-E**
D05S-5H-115AL-**
DG4S4-010B-WL-B-**
Single Solenoid, 2 Position
Spring Offset/Spring Center
All Ports Open
Indicator Light
3500 - 115 VAC
Terminal Box
10
7141 NCH SS-G03-A5-FR-D2-E**
D05SX-5B-24DL-**
DG4S4-012B-WL-H-**
Single Solenoid, 2 Position,
Spring Offset/Spring Center
All Ports Blocked, Shockless Type,
Indicator Light
3500 21.1 24 VDC
Terminal Box
63
7143 NCH SS-G03-A5-FR-E115-E**
D05SX-5B-115AL-**
DG4S4-012B-WL-B-**
Single Solenoid, 2 Position,
Spring Offset/Spring Center,
All Ports Blocked, Shockless Type,
Indicator Light
3500 21.1 115 VAC
Rectified
Terminal Box
5
7144 NCH SS-G03-A5-R-C115-E**
D05S-5B-115AL-**
DG4S4-012B-WL-B-**
Single Solenoid, 2 Position,
Spring Offset/Spring Center,
All Ports Blocked,
Indicator Light
3500 21.1 115 VAC
Terminal Box
5
7145 NCH SS-G03-A5-R-D2-E**
D05S-5B-24DL-**
DG4S4-012B-WL-H-**
Single Solenoid, 2 Position,
Spring Offset/Spring Center
All Ports Blocked,
Indicator Light
3500 21.1 24 VDC
Terminal Box
3
7195 NCH SS-G03-H5-FR-E115-E**
D05SX-5BR-115AL-**
DG4S4-012BL-WL-B-**
Single Solenoid, 2 Position,
Spring Offset/Spring Center
All Ports Blocked, Shockless Type
Indicator Light
3500 21.1 115 VAC
Rectified
Terminal Box
1
7196 NCH SS-G03-H5-R-D1-E**
D05S-5BR-12DL-**
DG4S4-012BL-WL-G-**
Single Solenoid, 2 Position,
Spring Offset/Spring Center,
All Ports Blocked
Indicator Light
3500 21.1 12 VDC
Terminal Box
4
7197 NCH SS-G03-H5-R-D2-E**
D05S-5BR-24DL-**
DG4S4-012BL-WL-H-**
Single Solenoid, 2 Position,
Spring Offset/Spring Center,
All Ports Blocked
Indicator Light
3500 21.1 24 VDC
Terminal Box
5
 

 
SIZE D05
DOUBLE SOLENOID 2 POSITION DETENT TYPE
 

Part Numbers provided for reference only!
Please refer to symbol and description for exact specifications!

 
Item# Compare to Nachi #
Compare to Hyvair #
Compare to Vickers #
JIS Symbol
(Click o Enlarge)
Description Max Pressure
PSI
Max. Flow
GPM
Coil &
Voltage
In Stock
Qty
7181 NCH SS-G03-E2X-R-C115-E**
D05S-3A8-115AL-**
DG4S4-01?N-WL-B-**
Double Solenoid, 2 Position,
Detent, Closed Crossover,
P to A, B & T Blocked
Indicator Light
3500 13.2 115 VAC
Terminal Box
5
7088 NCH SA-G03-E3X-C230-E**
D05SD-3A-230A-**
DG4S4-012N-U-D-**
Double Solenoid, 2 Position,
Detent, Closed Crossover,
P to A, B to T
3500 21.1 230 VAC
DIN Terminal
3
7089 NCH SA-G03-E3X-D1-E**
D05SD-3A-12D-**
DG4S4-012N-U-G-**
Double Solenoid, 2 Position,
Detent, Closed Crossover,
P to A, B to T
3500 21.1 12 VDC
DIN Terminal
3
7182 NCH SS-G03-E3X-FR-E115-E**
D05SX-3A-115AL-**
DG4S4-012N-WL-B-**
Double Solenoid, 2 Position,
Detent, Closed Crossover,
Shockless Type, P to A, B to T),
Indicator Light
3500 21.1 115 VAC
Rectified
Terminal Box
15
7184 NCH SS-G03-E3Z-FR-E115-E**
D05SX-3AY-115AL-**
DG4S4-010N-WL-B-**
Double Solenoid, 2 Position,
Detent, Open Crossover,
P to A, B to T, Shockless Type
Indicator Light
3500 21.1 115 VAC
Rectified
Terminal Box
4
7185 NCH SS-G03-E3Z-R-C115-E**
D05S-3AY-115AL-**
DG4S4-010N-WL-B-**
Double Solenoid, 2 Position,
Detent, Open Crossover,
P to A, B to T,
Indicator Light
3500 21.1 115 VAC
Terminal Box
25
7188 NCH SS-G03-E3Z-R-D1-E**
D05S-3AY-12DL-**
DG4S4-010N-WL-G-**
Double Solenoid, 2 Position,
Detent, Open Crossover,
P to A, B to T,
Indicator Light
3500 21.1 12 VDC
Terminal Box
1
 

 
SIZE D05
DOUBLE SOLENOID 3 POSITION SPRING CENTER TYPE
 

Part Numbers provided for reference only!
Please refer to symbol and description for exact specifications!

 
Item# Compare to Nachi #
Compare to Hyvair #
Compare to Vickers #
JIS Symbol
(Click o Enlarge)
Description Max Pressure
PSI
Max. Flow
GPM
Coil &
Voltage
In Stock
Qty
7146 NCH SS-G03-C1-FR-D1-E**
D05SX-2K-12DL-**
DG4S4-013C-WL-G-**
Double Solenoid, 3 Position,
Spring Center, A to T, T & B Blocked
Shockless Type,
Indicator Light
3500 21.1 12 VDC
Terminal Box
3
7147 NCH SS-G03-C1-FR-E115-E**
D05SX-2K-115AL-**
DG4S4-013C-WL-B-**
Double Solenoid, 3 Position,
Spring Center, A to T, T & B Blocked
Shockless Type,
Indicator Light
3500 21.1 115 VAC
Rectified
Terminal Box
4
7148 NCH SS-G03-C1-R-D1-E**
D05S-2K-12DL-**
DG4S4-013C-WL-G-**
Double Solenoid, 3 Position,
Spring Center, A to T, T & B Blocked
Indicator Light
3500 21.1 12 VDC
Terminal Box
5
7149 NCH SS-G03-C2-R-C115-E**
D05S-2J-115AL-**
DG4S4-01?C-WL-B-**
Double Solenoid, 3 Position,
Spring Center, A to P, T & B Blocked
Indicator Light
3500 21.1 115 VAC
Terminal Box
4
7153 NCH SS-G03-C4-FR-D1-E**
D05SX-2H-12DL-**
DG4S4-010C-WL-G-**
Double Solenoid, 3 Position,
Spring Center, All Ports Open
Shockless Type,
Indicator Lights
3500 21.1 12 VDC
Terminal Box
20
7154 NCH SS-G03-C4-FR-D2-E**
D05SX-2H-24DL-**
DG4S4-010C-WL-H-**
Double Solenoid, 3 Position,
Spring Center, All Ports Open
Shockless Type,
Indicator Lights
3500 21.1 24 VDC
Terminal Box
23
7155 NCH SS-G03-C4-R-C230-E**
D05S-2H-230AL-**
DG4S4-010C-WL-D-**
Double Solenoid, 3 Position,
Spring Center, All Ports Open
Indicator Lights
3500 21.1 230 VAC
Terminal Box
15
7156 NCH SS-G03-C4-R-D2-E**
D05S-2H-24DL-**
DG4S4-010C-WL-H-**
Double Solenoid, 3 Position,
Spring Center, All Ports Open
Indicator Lights
3500 21.1 24 VDC
Terminal Box
9
7157 NCH SS-G03-C5-FR-D2-E**
D05SX-2B-24DL-**
DG4S4-012C-WL-H-**
Double Solenoid, 3 Position,
Spring Center, All Ports Blocked
Shockless Type, Indicator Light
3500 21.1 24 VDC
Terminal Box
1
7158 NCH SS-G03-C5-FR-E115-E**
D05SX-2B-115AL-**
DG4S4-012C-WL-B-**
Double Solenoid, 3 Position,
Spring Center, All Ports Blocked
Shockless Type, Indicator Light
3500 21.1 115 VAC
Rectified
Terminal Box
2
7159 NCH SS-G03-C5-R-D1-E**
D05S-2B-12DL-**
DG4S4-012C-WL-G-**
Double Solenoid, 3 Position,
Spring Center, All Ports Blocked
Indicator Light
3500 21.1 12 VDC
Terminal Box
15
7161 NCH SS-G03-C5-R-C115-E**
D05S-2B-115AL-**
DG4S4-012C-WL-B-**
Double Solenoid, 3 Position,
Spring Center, All Ports Blocked
Indicator Light
3500 21.1 115 VAC
Terminal Box
1
7162 NCH SS-G03-C5-R-C230-E**
D05S-2B-230AL-**
DG4S4-012C-WL-D-**
Double Solenoid, 3 Position,
Spring Center, All Ports Blocked
Indicator Light
3500 21.1 230 VAC
Terminal Box
5
7163 NCH SS-G03-C5-R-D2-E**
D05S-2B-24DL-**
DG4S4-012C-WL-H-**
Double Solenoid, 3 Position,
Spring Center, All Ports Blocked
Indicator Light
3500 21.1 24 VDC
Terminal Box
10
7164 NCH SS-G03-C6-FR-D2-E**
D05SX-2F-24DL-**
DG4S4-016C-WL-H-**
Double Solenoid, 3 Position,
Spring Center, Pressure Port Blocked Center,
A & B to T, Motor, Float,
Shockless Type, Indicator Light
3500 21.1 24 VDC
Terminal Box
3
7167 NCH SS-G03-C6-R-C230-E**
D05S-2F-230AL-**
DG4S4-016C-WL-D-**
Double Solenoid, 3 Position,
Spring Center, Pressure Port Blocked Center,
A & B to T, Motor, Float, Indicator Light
3500 21.1 230 VAC
Terminal Box
10
7168 NCH SS-G03-C6-R-D1-E**
D05S-2F-12DL-**
DG4S4-016C-WL-G-**
Double Solenoid, 3 Position,
Spring Center, Pressure Port Blocked Center,
A & B to T, Motor, Float, Indicator Light
3500 21.1 12 VDC
Terminal Box
25
7169 NCH SS-G03-C6-R-D2-E**
D05S-2F-24DL-**
DG4S4-016C-WL-H-**
Double Solenoid, 3 Position,
Spring Center, Pressure Port Blocked Center,
A & B to T, Motor, Float, Indicator Light
3500 21.1 24 VDC
Terminal Box
10
7170 NCH SS-G03-C6-R-E115-E**
D05S-2F-115AL-**
DG4S4-016C-WL-B-**
Double Solenoid, 3 Position,
Spring Center, Pressure Port Blocked Center,
A & B to T, Motor, Float, Indicator Light
3500 21.1 115 VAC
Rectified
Terminal Box
20
7086 NCH SA-G03-C7Y-D1-E**
D05SD-2C-12D-**
DG4S4-018C-U-G-**
Double Solenoid, 3 Position,
Spring Center, A & B Blocked,
P to C, Tandem Center
3500 13.2 12 VDC
DIN Connector
9
7172 NCH SS-G03-C7Y-E115-E**
D05S-2C-115A-**
DG4S4-018C-W-B-**
Double Solenoid, 3 Position,
Spring Center, A & B Blocked,
P to C, Tandem Center
3500 13.2 115 VAC
Rectified
Terminal Box
5
7173 NCH SS-G03-C7Y-FR-D1-E**
D05SX-2C-12DL-**
DG4S4-018C-WL-G-**
Double Solenoid, 3 Position,
Spring Center, A & B Blocked,
P to C, Tandem Center,
Shockless Type, Indicator Light
3500 13.2 12 VDC
Terminal Box
5
7174 NCH SS-G03-C7Y-FR-D2-E**
D05SX-2C-24DL-**
DG4S4-018C-WL-H-**
Double Solenoid, 3 Position,
Spring Center, A & B Blocked,
P to C, Tandem Center,
Shockless Type, Indicator Light
3500 13.2 24 VDC
Terminal Box
2
7175 NCH SS-G03-C7Y-R-C115-E**
D05S-2C-115AL-**
DG4S4-018C-WL-B-**
Double Solenoid, 3 Position,
Spring Center, A & B Blocked,
P to C, Tandem Center,
Indicator Light
3500 13.2 115 VAC
Terminal Box
15
7176 NCH SS-G03-C7Y-R-C230-E**
D05S-2C-230AL-**
DG4S4-018C-WL-D-**
Double Solenoid, 3 Position,
Spring Center, A & B Blocked,
P to C, Tandem Center,
Indicator Light
3500 13.2 230 VAC
Terminal Box
20
7178 NCH SS-G03-C8-FR-E115-E**
D05SX-2C5-115AL-**
DG4S4-011C-WL-B-**
Double Solenoid, 3 Position,
Spring Center, B Blocked, A & P to T,
Shockless Type, Indicator Light
3500 13.2 115 VAC
Rectified
Terminal Box
1
7179 NCH SS-G03-C8-R-D2-E**
D05S-2C5-24DL-**
DG4S4-011C-WL-H-**
Double Solenoid, 3 Position,
Spring Center, B Blocked, A & P to T,
Indicator Light
3500 13.2 24 VDC
Terminal Box
5
7087 NCH SA-G03-C9-C230-E**
D05SD-2T-230A-**
DG4S4-017C-U-D-**
Double Solenoid, 3 Position,
Spring Center, T Blocked, P to A & B
3500 21.1 230 VAC
DIN Connector
10
7180 NCH SS-G03-C9-R-C115-E**
D05S-2T-115AL-**
DG4S4-017C-WL-B-**
Double Solenoid, 3 Position,
Spring Center, T Blocked, P to A & B,
Indicator Light
3500 21.1 115 VAC
Terminal Box
1
             

 


 

Vickers DG5S-8 Compatible,
D08 / ISO-08 Solenoid Controlled, Pilot Operated Directional Valves
 

 

Valve Size: D08 (Formerly D06)
Mounting: D08 Subplate Mounting
Made in Japan                Spg. Weight: 35 LBS
 

 

 SIZE D08
SINGLE SOLENOID 2 POSITION SPRING OFFSET TYPE 

 

Part Numbers provided for reference only!
Please refer to symbol and description for exact specifications!

 
Item# Compare to Nachi #
Compare to Hyvair #
Compare to Vickers #
JIS Symbol
(Click o Enlarge)
Description Max Pressure
PSI
Flow
GPM
Rated / Max.
Coil &
Voltage
In Stock
Qty
7040-NCH DSA-G06-A3X-D2-E**
D08SD-1A-24D-**
DG5S-8-S-2A-U-H-**
Single Solenoid, 2 Position,
Spring Offset, Closed Crossover
(P to A, B to T)
4500 80 / 150 24 VDC
DIN Connector
2
7044 NCH DSS-G06-A3X-AFR-E115-E**
D08SX-1A-115EL-**
DG5S-8-S-2A-T-WL-B-**
Single Solenoid, 2 Position,
Spring Offset, Closed Crossover
(P to A, B to T)
Internal Pilot Internal Drain
Shockless Type, Indicator Light
4500 80 / 150 115 V
Rectified
Terminal Box
3
 

 

SIZE D08
DOUBLE SOLENOID 2 POSITION DETENT 

 

Part Numbers provided for reference only!
Please refer to symbol and description for exact specifications!

 
Item# Compare to Nachi #
Compare to Hyvair #
Compare to Vickers #
JIS Symbol
(Click o Enlarge)
Description Max Pressure
PSI
Flow
GPM
Rated / Max.
Coil &
Voltage
In Stock
Qty
7043 NCH DSA-G06-E3X-D2-E**
D08SD-3A-24D-**
DG5S-8-S-2N-U-H-**
Double Solenoid, 2 Position,
Detent, Closed Crossover
(P to A, B to T)
4500 80 / 150 24 VDC
DIN Connector
1
7066 NCH DSS-G06-E3X-R-D2-E**
D08S-3A-24DL-**
DG5S-8-S-2N-WL-H-**
Double Solenoid, 2 Position,
Detent, Closed Crossover
(P to A, B to T)
Indicator Light
4500 80 / 150 24 VDC
Terminal Box
5
7067 NCH DSS-G06-E3Z-ER-C115-E**
D08S-3A-115AL-**
DG5S-8-S-0N-E-WL-B-**
Double Solenoid, 2 Position,
Detent, Open Crossover
(P to A, B to T)
External Pilot & External Drain
Indicator Light
4500 80 / 150 115 VAC
Terminal Box
2
7068 NCH DSS-G06-E3Z-R-C115-E**
D08S-3A-115AL-**
DG5S-8-S-0N-WL-B-**
Double Solenoid, 2 Position,
Detent, Open Crossover
(P to A, B to T)
Indicator Light
4500 80 / 150 115 VAC
Terminal Box
1
 

 
SIZE D08
DOUBLE SOLENOID 3 POSITION SPRING CENTER TYPE

 

Part Numbers provided for reference only!
Please refer to symbol and description for exact specifications!

 
Item# Compare to Nachi #
Compare to Hyvair #
Compare to Vickers #
JIS Symbol
(Click o Enlarge)
Description Max Pressure
PSI
Flow
GPM
Rated / Max.
Coil &
Voltage
In Stock
Qty
7041 NCH DSA-G06-C1-D2-E**
D08SD-2K-24D-**
DG5S-8-S-?C-U-H-**
Double Solenoid, 3 Position
Spring Centered,
A to T, P and B Ports Blocked Center
4500 80 / 150 24 VDC
DIN Connector
8
7046 NCH DSS-G06-C1-R-C115-E**
D08S-2K-115AL-**
DG5S-8-S-?C-WL-B-**
Double Solenoid, 3 Position
Spring Centered,
A to T, P and B Ports Blocked Center
Indicator Light
4500 80 / 150 115 VAC
Terminal Box
2
7048 NCH DSS-G06-C4-AER-D-E**
D08S-2H-12DL-**
DG5S-8-S-0C-E-T-WL-G-**
Double Solenoid, 3 Position
Spring Centered,
All Ports Open Center
External Pilot & Internal Drain
Indicator Light
4500 80 / 150 12 VDC
Terminal Box
18
7052 NCH DSS-G06-C4-R-C230-E**
D08S-2H-230AL-**
DG5S-8-S-0C-WL-D-**
Double Solenoid, 3 Position
Spring Centered,
All Ports Open Center
Indicator Light
4500 80 / 150 230 VAC
Terminal Box
3
7054 NCH DSS-G06-C5-AER-D1-E**
D08S-2B-12DL-**
DG5S-8-S-2C-E-T-WL-G-**
Double Solenoid, 3 Position
Spring Centered,
All Ports Blocked Center
External Pilot & Internal Drain
Indicator Light
4500 80 / 150 12 VDC
Terminal Box
1
7055 NCH DSS-G06-C5-ER-D2-E**
D08S-2B-24DL-**
DG5S-8-S-2C-E-WL-H-**
Double Solenoid, 3 Position
Spring Centered,
All Ports Blocked Center
External Pilot & External Drain
Indicator Light
4500 80 / 150 24 VDC
Terminal Box
2
7056 NCH DSS-G06-C6-D1-E**
D08S-2F-12D-**
DG5S-8-S-6C-W-G-**
Double Solenoid, 3 Position
Spring Centered,
Pressure Port Blocked Center,
A & B to T, Motor, Float
4500 80 / 150 12 VDC
Terminal Box
1
7058 NCH DSS-G06-C6-R-D2-E**
D08S-2F-24DL-**
DG5S-8-S-6C-WL-H-**
Double Solenoid, 3 Position
Spring Centered,
Pressure Port Blocked Center,
A & B to T Motor, Float
Indicator Light
4500 80 / 150 24 VDC
Terminal Box
48
7060 NCH DSS-G06-C7X-AER-D1-E**
D08S-2C-12DL-**
DG5S-8-S-4C-E-T-WL-G-**
Double Solenoid, 3 Position
Spring Centered,
Closed Crossover, P to T, A & B Blocked, Tandem Center
External Pilot & Internal Drain
Indicator Light
4500 80 / 150 12 VDC
Terminal Box
5
7061 NCH DSS-G06-C7Y-AER-D1-E**
D08S-2C-12DL-**
DG5S-8-S-8C-E-T-WL-G-**
Double Solenoid, 3 Position
Spring Centered,
Open Crossover with Taper,
P to T, A & B Blocked, Tandem Center
External Pilot & Internal Drain,
Indicator Light
4500 80 / 150 12 VDC
Terminal Box
2
7062 NCH DSS-G06-C7Y-AER-D2-E**
D08S-2C-24DL-**
DG5S-8-S-8C-E-T-WL-H-**
Double Solenoid, 3 Position
Spring Centered,
Open Crossover with Taper,
P to T, A & B Blocked, Tandem Center
External Pilot & Internal Drain
Indicator Light
4500 80 / 150 24 VDC
Terminal Box
1
7063 NCH DSS-G06-C7Y-ER-D2-E**
D08S-2C-24DL-**
DG5S-8-S-8C-E-WL-H-**
Double Solenoid, 3 Position
Spring Centered,
Open Crossover with Taper,
P to T, A & B Blocked, Tandem Center
External Pilot & External Drain
Indicator Light
4500 80 / 150 24 VDC
Terminal Box
2
7064 NCH DSS-G06-C7Y-R-C115-E**
D08S-2C-115AL-**
DG5S-8-S-8C-WL-B-**
Double Solenoid, 3 Position
Spring Centered,
Open Crossover with Taper,
P to T, A & B Blocked, Tandem Center
Indicator Light
4500 80 / 150 115 VAC
Terminal Box
1
7065 NCH DSS-G06-C7Y-R-C230-E**
D08S-2C-230AL-**
DG5S-8-S-8C-WL-D-**
Double Solenoid, 3 Position
Spring Centered,
Open Crossover with Taper,
P to T, A & B Blocked, Tandem Center
Indicator Light
4500 80 / 150 230 VAC
Terminal Box
1
             

 

 

Don't see it here ????    Call 773-763-2100

We have more items in stock than we are able to list !
If you don't see it on our site or would like price and delivery on an item
that you did see  
Call 773-763-2100
Fax   773-763-6877

 or  
e-mail
sales@oemsurplus911.com

 

vmda.gif (9904 bytes)
We accept all major credit cards.

DYMATIC, INC.

5328  N. NORTHWEST HWY.
CHICAGO, IL 60630-1137
TEL:   773-763-2100
FAX:   773-763-6877

Due to the nature of our business, prices, specifications, availability's are subject to change without notice.
Manufacturers names and p/n's are used for reference only, and are the property of the companies.
VitonŽ is a registered trademark of DuPoint Performance Elastomers
Minimum order applies in some cases  !!!!!!